CONCRETE BOOM. RISK & HAZARD ASSESSMENT. PLANT RISK & HAZARD ANALYSIS. MELBOURNE, VICTORIA. 0475 217 533. The Employer with a CONCRETE BOOM have obligations under OHS/WHS legislation to provide that CONCRETE BOOM in a safe condition. Part of this safety process requires a plant risk & hazard assessment of the CONCRETE …
Concrete placement booms can have a greater risk of failure due to the cyclic load of the pulsating pump. The information supplied below deals with the key risks associated with components of the concrete pumping system. Specific risk controls are recommended for each of these components. CONCRETE PUMPING RISK CONTROLS FOR CONCRETE
Jun 13, 2015· Concrete Pouring Risk Assessment Concrete gets into eyes from the last point of hoses There are chances to fall from mesh which might injury your hand, ankles, arms, legs, etc. Since, the concrete and aggregate comes out with high pressure, so if it will touch the human skin then skin will get burned or get rashes.Estimated Reading Time: 2 mins
7 rows· placement below outrigger feet to support the pump. C, S,O Prior to and during works 5 2 M Crush ...Hazard(s) Identified Hazard(s) Ident…- RISK RISK Hazard(s) Identified Hazard(s) Ident… Control Measures By Whom By When CONCRETE PUMP SET UP … Collapse or s… S, O, T & C 5 3 CONCRETE PUMP SET UP / …Crush or impac… S, O, T & C 4 3 See all 7 rows on www.shaylerconcretepumping.co.uk
Fig 2: Concrete Placing Boom 2.9 Concrete Pump: An item of plant used for pumping or spraying concrete. It works by pistons or a rotary pump, whereby the material to be transported is conveyed to the placing position through a pipeline alone or through a pipeline attached to a concrete placing boom.Missing: risk assessment
hoses from boom Concrete Gang L Medium to Severe (possible death) Move away from end hose during boom movement. Concrete Gang to be alert Broken limbs, severe injury caused by whiplash of placing hoses. Concrete Gang L Severe or death . Do not kink placing hoses in the ground line. Do not attempt to pump very old concrete or concrete other than a pump mix. …
Purpose
Total Concrete Ltd Produced at www.darleypcm.com Concreting contact on site Risk Assessment pg. 1/8 Risk Assessment Activity: Concreting contact on site Reference: RA076 Task Description: Assessor: Andrew Shaw Date: 26/04/2017 Assessment of Risk Hazard Likelihood Severity Risk Exposure to cement dust Med Low Low Shovelling materials Low …
· Web viewSafety decal in place: “Caution: concrete placing boom not to be used as a crane” ... Plant Risk Assessment specific to make and model. Daily Pre-start book specific to plant type & concrete pump log book (or combined book) Maintenance history (minimum of 3 months records)
placing boom, the planning and supervision of their use, and the competence of the operator and other personnel. If any of these are deficient, the risk of a serious accident increases significantly, so it is essential that site managers ensure that all concrete pumping operations are planned, supervised and carried out safely.[PDF]CONCRETE PUMPING RISK ASSESSMENT 6
Concrete Pump Risk Assessment. Concrete boom and line pumps can be dangerous equipment if not operated safely. That's why all of our Safe Work Method Statements include a Risk Assessment matrix. This document is tailored specifically for your industry, so you can rate your risk right in the SWMS and ensure you're meeting all safety requirements.
Assessment of risk. Once all the health and safety procedures listed above have been carried out, an overall assessment can now be made as to whether it is safe to proceed with the work in question. This is graded over five levels: 1. Very Low Risk – safe to proceed work to control measures; 2. Low Risk – safe to proceed with caution; 3.
hoses from boom Concrete Gang L Medium to Severe (possible death) Move away from end hose during boom movement. Concrete Gang to be alert Broken limbs, severe injury caused by whiplash of placing hoses. Concrete Gang L Severe or death . Do not kink placing hoses in the ground line. Do not attempt to pump very old concrete or concrete other than ...
Dec 13, 2020· Concrete Pumping Risk Assessment. by HSE Documents on December 13, 2020 in Risk Assessment. MTMCP- (The mobile truck-mounted concrete pump) is developed to supply concrete mixture from the machine’s delivery hopper to designated point/place. This is accomplished via a hydraulically energized pump, through pipe sections attached to an ...
Concrete Burns • Sand contained in fresh concrete is abrasive to bare skin • Portland is an alkaline. Strong bases (ph of 12-13) are just as hazardous as strong acids to the skin but have no initial signs of pain such as a burning sensation. • Drying Portland is hygroscopic – it absorbs water. Portland needs water to harden.
Apr 07, 2014· Hazard identification tool – Concrete placement. This publication is for: Builder Employee / worker Employer. This educational article has been developed to assist in the identification of occupational safety and health (OSH) hazards. The hazard identification tools were developed following interviews with principal contractors and ...
placing boom, the planning and supervision of their use, and the competence of the operator and other personnel. If any of these are deficient, the risk of a serious accident increases significantly, so it is essential that site managers ensure that all concrete pumping operations are planned, supervised and carried out safely.
PLANT HAZARD RISK ASSESSMENT WORKSHEET (PHA) Revision: B Aconex Ref: NWRLOTS-NRT-ADM-SF-FRM-300102 PIMS Ref: PIMS-FM-01/01/014 Page 1 of 15 Date: 12/11/2015 When printed this document is an uncontrolled version and should be checked against the electronic version for validity
If it is a mobile boom pump, does it have current plant registration? 9. Does the operator hold a current ticket for the operation of a mobile concrete placing boom? 10. Does the truck have a Queensland Modification Plate (Blue Plate) fitted? This …
Photograph 4: Concrete placement boom overturned when the boom slewed over short legged outriggers on one side of the vehicle. Risk management Work health and safety laws require a PCBU to manage all work health and safety risks, so that the health and safety of workers and other people are not affected by an organisation’s conduct.
Concrete Placing Boom . Categories: Boom, High Risk A concrete placing boom is a mobile truck mounted plant incorporating a knuckle boom. It is capable of power operated slewing and luffing to place concrete by pumping it through a pipeline attached to, or forming part of, the boom of the plant.
risk assessment and hazard prevention strategies, including hierarchy of control as applied to the positioning and safe operation of the concrete placing boom (particular awareness of the risks associated with overhead powerlines/electrical cables, ground conditions, wind, pedestrians and …
Concrete-Placing Unit Concrete-Placing Boom Pump 16 Concrete Delivery Concrete Delivery Truck 17 Cranes Telescopic Handling Crane 19 Truck-Mounted Crane 20 ... Risk assessment/Hazard checklist 5) Current Road Registration (if being driven on public roads) 6) Lifting point certification (if item is to be lifted) ...[PDF]CONCRETE PUMPING RISK ASSESSMENT 6
The Concrete Placing Booms Global Market Research Report 2021 provides comprehensive information on future trends, ... 3.4.1 Risk Assessment on COVID-19 3.4.2 Assessment of the Overall Impact of COVID-19 on the Industry 3.4.3 Pre …
AINTREE Concrete Pumping Risk Assessment – TRUCK MOUNTED MOBILE CONCRETE PUMP Page Reacting to - BLOCKAGES Where possible, the CPO will stop the pump action (emergency stop buttons are provided on the truck/ pump body, and upon the remote control unit, or reverse the pumping direction. The CPO will ensure all persons retreat to a safe distance …
Concrete Burns • Sand contained in fresh concrete is abrasive to bare skin • Portland is an alkaline. Strong bases (ph of 12-13) are just as hazardous as strong acids to the skin but have no initial signs of pain such as a burning sensation. • Drying Portland is hygroscopic – it absorbs water. Portland needs water to harden.
Jun 04, 2013· Of all the equipment that has changed concrete construction over the past 40 years, the concrete boom pump is number one for increasing productivity and reducing labor. A concrete pump is a very large and powerful piece of equipment that can provide great benefits on a concrete project but it can also be dangerous without proper set-up and safety procedures.
· Web viewCJR CONCRETE PUMPING LTD – CONCRETE PUMPING RISK ASSESSMENT ... all personnel should remain clear of the delivery hose and placing boom. Under no circumstances should any unauthorised personnel attempt to open the pipeline. ... severe injury caused by whiplash of placing hoses. Concrete Gang L Severe or death Do not kink placing hoses in …
of placing line, a three-, four-, or five-section boom pump or a trailer pump with a placing boom, your safety and the safety of other personnel involved with the concrete operation should be your main concern. A worn-out cliché ―The life you save may be your own‖ is certainly true as a concrete pump operator.
If it is a mobile boom pump, does it have current plant registration? 9. Does the operator hold a current ticket for the operation of a mobile concrete placing boom? 10. Does the truck have a Queensland Modification Plate (Blue Plate) fitted? This …
Concrete-Placing Unit Concrete-Placing Boom Pump 16 Concrete Delivery Concrete Delivery Truck 17 Cranes Telescopic Handling Crane 19 Truck-Mounted Crane 20 ... Risk assessment/Hazard checklist 5) Current Road Registration (if being driven on public roads) 6) Lifting point certification (if item is to be lifted) ...
The purpose of this method statement is to illustrate how the existing fence and shelters will be removed from site in proper and safe way. The scope of this method of statement is to cover the demolishing methodology of the following: Chain link fence (internal & external) Shelters Toilet Tents Water station Lighting pole Road…
Nov 03, 2021· Conditional. Required for:Cranes, Telehandlers & Piling Rigs with a rated capacity greater than 10TBoom-type EWP's (applies nationally)Scissor Lift & Z-type lifts greater than 2.4m (applies in VIC only)Concrete Placing booms manufactured / imported on or after 01/01/2015. Other Relevant Documentation. ChekRite Portal.
Jun 17, 2021· Safety issues. Employees in the immediate vicinity of a raised concrete-placing boom are at risk of death or serious injury in the event of a structural or mechanical failure of the boom or stabilising outriggers. Inadequate inspection and maintenance of critical components (such as the slew ring assembly, boom pins, bushes, welds, king post ...
· Web viewCONCRETE BOOM PUMP TRUCK PRE-ACCEPTANCE CHECKLIST. 0. 0. 0. Revision No: 1. Document Number: JH-FRM-PAE-001-28. Page 2 of 2. When printed this document is an uncontrolled version and must be checked against the IMS electronic version for validity
The Concrete Placing Booms Global Market Research Report 2021 provides comprehensive information on future trends, opportunities and challenges, joint segmentation with leading manufacturers,...Employee dies when struck by a concrete-placing boom …
The American Concrete Pumping Association requires that the boom tip and any other section of the boom be at least 17 feet (5 meters) from power lines. Depth perception when judging far away objects is seldom reliable, and should be avoided when operators are placing their booms.
The Concrete Placing Booms Global Market Research Report 2021 provides comprehensive information on future trends, opportunities and challenges, joint segmentation with leading manufacturers,...
of placing line, a three-, four-, or five-section boom pump or a trailer pump with a placing boom, your safety and the safety of other personnel involved with the concrete operation should be your main concern. A worn-out cliché ―The life you save may be your own‖ is certainly true as a concrete pump operator.
Safe Work Method Statement Concrete. SWMS for concreting focuses on identifying hazards, assessing risks and evaluating how to control risk, and includes: Risk assessment matrix to determine the risk level. Hierarchy of risk controls for controlling hazards and risks in the workplace. SWMS steps to perform work task.
Jul 06, 2012· Concrete pumping is the most efficient way to place concrete and if all safety concerns are addressed before, during, and after a placement, the chance for accidents will be minimized. If you have questions about a placement requiring a concrete pump, ask the concrete pumping contractor to visit the jobsite and help you with the pre-pour plan.
Training on the job to ensure awareness of potential risk if screed is left to set in pipe. Periodic supervision. Unlikely (2) Unlikely (2) Unlikely (2) (3x2) 6 (5x2) 10 (5x2) 10 Low Low Low Worst Case Outcome Likelihood given precautions in place 10 8 5 3 1 10 8 5 2 1 Fatality Severe injury Lost time injury Minor injury
the form of a toolbox talk, in accordance with the method statement and Risk assessment. This will ensure that all members of the team are aware of the sequence of works and the hazards present. • The Slinger/Signaller (SS) under the supervision of the lift supervisor will then check the condition of the lifting accessories for any defects.
Nov 18, 2020· Reverse beeper, flashing beacon, CCTV and or mirrors fitted. 5. Defective skids removed immediately from the line. 6. Heavy duty gloves to be worn by operatives handling skids. 7. All engines guards and covers to be in position and secured. 8. Windows, lights, mirrors and camera lens to be kept clean at all times.
in the boom pipeline, all personnel should remain clear of the delivery hose and the placing boom. (The danger zone is the area around the delivery hose in which the delivery hose can strike out. The diameter of the zone is twice the length of the delivery hose). s during the pour, the concrete pump operator must stop pumping immediately
Unmatched in the industry, Concord placing booms provide the highest free-standing heights and offer a wide range of mounting and climbing configurations. Concord placing booms are ideal for working on high-rise buildings, treatment plants, precast plants, bridges, dams, and extreme applications. Combined with the right concrete pump, our ...
· Web viewCONCRETE BOOM PUMP TRUCK PRE-ACCEPTANCE CHECKLIST. 0. 0. 0. Revision No: 1. Document Number: JH-FRM-PAE-001-28. Page 2 of 2. When printed this document is an uncontrolled version and must be checked against the IMS electronic version for validity
(PB) Concrete Placing Boom Training and Assessment (2 days) CPCCLBM3001 Licence to operate a concrete placing boom. Course Objective To provide applicants with the practical skills and knowledge to safely operate a concrete placing boom (PB) in accordance with Safe Work Australia’s National Standard for Licencing Persons Performing HRW.
Cement Concrete & Aggregates Australia (CCAA) is the peak body representing the $7 billion a year cement, concrete and aggregate industries. CCAA represents the interests of its members to governments and the wider community on issues as diverse as resource access and security, transport, workplace health and safety, and the environment.
57th, Kexue Avenue, National HI-TECH Industrial Development Zone, Zhengzhou, China.
0086-371-86525099 (Office of the company)
0086-15136236223
E-mail : [email protected]